docs: finalize cross-platform support and portability guide
- Updated README.md with comprehensive installation and usage guides. - Added cross-platform command comparison table (Linux vs Windows). - Included portability instructions for USB drive execution. - Verified stable operation on Windows 10/11 (CMD/PowerShell) and Linux (Ubuntu/LMDE 7). - Synchronized default paths and fixed toggle command examples
This commit is contained in:
@@ -7,9 +7,10 @@ Designed for stability in production environments where reliability is key.
|
||||
|
||||
### 📋 Features
|
||||
* **Direct Socket Communication:** No heavy libraries like `pymodbus` required.
|
||||
* **Instance Protection:** Uses `fcntl` file locking to prevent race conditions during concurrent executions.
|
||||
* **Cross-Platform:** Full support for `Linux` and `Windows`.
|
||||
* **Health Checks:** Integrated `ICMP` ping check before command execution.
|
||||
* **Configurable:** All parameters (IP, Port, Channels) are stored in an external `.ini` file.
|
||||
* **Smart Paths:** Uses `pathlib` for automatic directory creation (e.g., `logs/` folder).
|
||||
* **Detailed Logging:** Full audit trail of all `ON/OFF/TOGGLE` actions.
|
||||
|
||||
---
|
||||
@@ -17,9 +18,8 @@ Designed for stability in production environments where reliability is key.
|
||||
### 💻 Requirements
|
||||
| Requirement | Value |
|
||||
| :--- | :--- |
|
||||
| **OS** | Linux (Ubuntu, Debian, LMDE, etc.) |
|
||||
| **Python** | 3.6+ |
|
||||
| **Permissions** | Write access to log/lock paths |
|
||||
| **OS** | Linux, Windows, FreeBSD |
|
||||
| **Python** | 3.6+ (standard library only) |
|
||||
|
||||
---
|
||||
|
||||
@@ -32,56 +32,58 @@ Designed for stability in production environments where reliability is key.
|
||||
| **`[modbus]`** | `coil_base` | Channel base num (`0` or `1`) | `1` |
|
||||
| **`[modbus]`** | `timeout` | Socket timeout (sec) (only view) | `1` |
|
||||
| **`[modbus]`** | `max_channel`| Max channel index (e.g., `7`). `7` for `coil_base=1` too. | `7` |
|
||||
| **`[paths]`** | `lock_file` | Path to `.lock` file | `/tmp/modbus.lock` |
|
||||
| **`[paths]`** | `log_file` | Path to `.log` file | `/tmp/modbus.log` |
|
||||
| **`[paths]`** | `lock_file` | Path to `.lock` file | `modbus.lock` |
|
||||
| **`[paths]`** | `log_file` | Path to `.log` file | `logs/modbus.log` |
|
||||
|
||||
**Tip**: It's better to specify relative names in default path values,
|
||||
so that they work "out of the box" everywhere:
|
||||
|
||||
---
|
||||
|
||||
### ⚙️ Installation & Setup
|
||||
### ⚙️ Installation & Portability
|
||||
The tool is fully portable and can be run directly from a USB drive or any local folder without system-wide installation.
|
||||
1. Clone the repository:
|
||||
```bash
|
||||
git clone https://github.com/andsyrovatko/s4k-modbus-relay-controller.git
|
||||
cd s4k-modbus-relay-controller
|
||||
```
|
||||
2. Configure the tool:
|
||||
Copy the example config and edit it with your device details:
|
||||
Copy the example config and edit it (the script will automatically find it in its own directory):
|
||||
* `Linux:`
|
||||
```bash
|
||||
cp config.ini.example config.ini
|
||||
nano config.ini
|
||||
cp config.ini.example config.ini && nano config.ini
|
||||
```
|
||||
3. Set executable permissions:
|
||||
* `Windows:`
|
||||
```bash
|
||||
copy config.ini.example config.ini
|
||||
```
|
||||
(then edit with any text editor)
|
||||
3. Permissions (`Linux only`):
|
||||
```bash
|
||||
chmod +x modbus_controller.py
|
||||
```
|
||||
|
||||
(to start script as `./modbus_controller.py` not `python modbus_controller.py`)
|
||||
---
|
||||
|
||||
### 🚀 Usage
|
||||
0. Use via cli or call from another soft:
|
||||
The script supports both Windows and Linux syntax. You can run it from any location by specifying the full path.
|
||||
|
||||
```bash
|
||||
# Get script help/usage info
|
||||
python3 modbus_controller.py
|
||||
# Output: modbus_controller.py <status|on|off|toggle> <channel>
|
||||
| Action | Linux | Windows (CMD/PowerShell) | Result |
|
||||
| :--- | :--- | :--- | :--- |
|
||||
| **Get Status** | `./modbus_controller.py status 1` | `python modbus_controller.py status 1` | Channel 1 is OFF |
|
||||
| **Turn ON** | `./modbus_controller.py on 1` | `python modbus_controller.py on 1` | Channel 1 is turned ON |
|
||||
| **Turn OFF** | `./modbus_controller.py off 1` | `python modbus_controller.py off 1` | Channel 1 is turned OFF |
|
||||
| **Toggle** | `./modbus_controller.py toggle 1` | `python modbus_controller.py toggle 1` | Channel 1 is turned OFF (if was ON) |
|
||||
|
||||
# Get channel status
|
||||
python3 modbus_controller.py status 8
|
||||
# Output: Channel 8 is OFF
|
||||
|
||||
# Turn a specific channel ON or OFF
|
||||
python3 modbus_controller.py on 8
|
||||
# Output: Channel 8 is turned ON
|
||||
|
||||
# Toggle channel state
|
||||
python3 modbus_controller.py toggle 8
|
||||
# Output: Channel 8 is turned ON
|
||||
### 📦 Portable Example (Windows)
|
||||
Run the script directly from your USB drive (e.g. `F:\`) by specifying the full path:
|
||||
```powershell
|
||||
python F:\ModBus\modbus_controller.py status 1
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
### ⚠️ Important Note
|
||||
[**!IMPORTANT**]\
|
||||
This version currently supports Linux only due to the use of fcntl for process locking. Windows support is planned for future releases.
|
||||
### [✓] Verified: Tested on Linux (LMDE 7) and Windows 11.
|
||||
|
||||
---
|
||||
|
||||
|
||||
Regular → Executable
+1
-1
@@ -4,7 +4,7 @@
|
||||
# Description : Control Modbus coils via TCP (Modbus RTU over TCP).
|
||||
# Usage : python3 modbus_controller.py <status|on|off|toggle> <channel>
|
||||
# Author : syr4ok (Andrii Syrovatko)
|
||||
# Version : 1.1.0b
|
||||
# Version : 1.1.0
|
||||
# =============================================================================
|
||||
import configparser
|
||||
import os
|
||||
|
||||
Reference in New Issue